Structure

Commands follow a simple “COMMAND+ARGUMENTS” structure, with the separator character being the semicolon.

Send the command followed by some number of arguments depending on the command. Always end the line with a “newline”.

Examples:

  • [COMMAND];[ARG_1];[ARG_2];;[ARG_N]
  • chan;1;0;0;1 - turns on channels 0 and 3, and turns 1 and 2 off (assuming there are exactly 4 output channels)

To view the current settings of any of the parameters you can control, simply use the commands below, but omit any arguments you would normally put after the commands.

Command Specification

A comprehensive set of command specifications can be found in the pressure_control_interface package. This documentation expands on the functionality of each command.

System Commands

Command Arguments Description
FIRMWARE n/a Return the firmware version
CMDSPEC n/a Return the internal version of the command spec used
ERROR n/a Return the error states of the pressure watchdogs (input and channels)

Basic Commands

Command Arguments Description
ON n/a Start the live pressure output
OFF n/a Stop the live pressure output
LOAD n/a Load settings from onboard storage
SAVE n/a Overwrite the current settings profile in onboard storage
MODE #1 int (enum) Set the control mode
    0 = direct control of valve states
    1 = pressure control using PID and sensors)
    2 = pressure trajectory following
    3 = pressure control with ramp from current setpoint to new one
ECHO #1 bool Set whether commands are echoed
    0 = Off - No commands are echoed back (silent mode)
    1 = On - commands are echoed back on the serial line. Command echos are always preceded by an underscore
TIME #1 int Set the desired loop time for measurement outputs (in ms)
UNITS #1 int (enum) Set the pressure units you want to use: {0: psi, 1: kPa, 2: bar, 3:atm}
  [#1;#2] Set the input and output units separately
    #1 int = input units: used for setting setpoints and loading trajectories
    #2 int = output units: used for displaying data
CURRTIME #1 int Set the current display time on the controller (in ms). Typically used to synchronize with other devices (i.e. set current time to zero when you start a trajectory)

NOTE: Units are converted at the command/output level. Pressures are always internally represented in psi regardless of what the units are set to.

Safety Settings

Command Arguments Description
MAXP #1 float Set the maximum pressure allowed. Pressures are clipped if outside this range when using the “SET” command, but not when loaded as part of a trajectory. (used for the pressure watchdog)
MINP #1 float Set the minimum pressure allowed. Pressures are clipped if outside this range when using the “SET” command, but not when loaded as part of a trajectory.
SPIKE #1 int Set the desired spike time for the channel watchdog (in ms). This is the minimum time above the threshold before watchdog triggers
MASTERP #1 bool use input pressure sensor for watchdog
  [#1;#2]  
    #1 bool = use input pressure sensor for watchdog
    #2 bool = pressure sensor data output on/off
MASTERMAXP [#1;#2] Set the maximum pressure before the master watchdog triggers, as well as the
    #1 float = maximum pressure threshold
    #2 int = minimum time above the threshold before watchdog triggers

Control Channels

Command Arguments Description
CHAN #1 bool Set all channels active or inactive
  [#1;#2;…;#N] list(bool) Set individual channels active *. Replace “#” with either 1 or 0 for on or off.
SET [#1;#2] Set the pressure setpoint of ALL pressure channels. This setting is only used if MODE is set to 1 or 3.
    #1 float = ramp time in seconds - only used if MODE is set to 3
    #2 float = Setpoint
  [#1;#2;…;#N;#N+1] list(float) Set the pressure setpoint of individual pressure channels*.
    #1 float = ramp time in seconds - only used if MODE is set to 3
    #2;…;#N+1 list(float) = Setpoints for each channel
VALVE #1 float Set the valve states of ALL pressure channels (can be -1.0 → 1.0). This setting is only used if MODE is set to 0.
    -1.0 = vent at full speed
    0.0 = idle (both valves in the pair are closed)
    1.0 = pressurize to full input pressure at full speed
  [#0;#1;…;#N-1] list(float) Set the valve state of individual channels* (float).

When setting things for individual channels, the number of arguments must equal the number of channels.

Controller Settings

Command Arguments Description
PID [#1; #2; #3; #4] Set the PID gains for one particular channel
    #1 int = Channel index
    #2 float = Proportional gain
    #3 float = Integral gain
    #4 float = Derivative gain
WINDOW #1 float Set the dead window for all channels. This is a window around the setpoint in which control is turned off. Default is 0 (control always on)
  [#0;#1;…;#N-1] list(float) Set the dead window for individual channels *.
INTSTART #1 float Set the window (in pressure space) around the setpoint in which the integrator works
VOFFSET [#1; #2; #3] Set the PWM offset values for valves one particular channel
    #1 int = Channel index
    #2 int = Supply valve offset (can be 0 → 255)
    #3 int = Vent valve offset (can be 0 → 255)

When setting things for individual channels, the number of arguments must equal the number of channels.

Set Up Trajectories

Command Arguments Description
TRAJCONFIG [#1; #2; #3; #4] Set the trajectory settings
    #1 int = Prefix length
    #2 int = Main trajectory length
    #3 int = Suffix length
    #4 bool = Run the suffix trajectory after stop
TRAJWRAP #1 bool Wrap the trajectory (Same functionality can be achieved using TRAJLOOP)
    0 = Off - trajectory excecutes once
    1 = On - loop over and over until stopped
TRAJLOOP #1 int Number of times to loop
    -1 = Loop Forever until the TRAJSTOP command is sent
    0 = Skip the main loop
    1,2,… = Do the main loop this many times
TRAJSPEED #1 float Stretch the speed of the trajectory
    1.0 - base speed
    >1.0 - Faster than base speed
    <1.0 - Slower than base speed (can never be 0; if 0 is sent, no changes are made)
TRAJSET [#1, #2, #3;…;#N+2] Set the main trajectory line by line
    #1 int = index (can be 0 → max_length-1)
    #2 float = time point
    #3;…;#N+2 list(float) = pressure setpoints for each channel, where the row is zero-padded if the number of inputs is less than the number of total channels
PREFSET [#1, #2, #3;…;#N+2] Set the prefix trajectory line by line (works exactly like TRAJSET)
SUFFSET [#1, #2, #3;…;#N+2] Set the prefix trajectory line by line (works exactly like TRAJSET)

Run Trajectories

Command Arguments Description
TRAJSTART [none] Start the trajectory from the beginning. Run suffix first, then run trajectory until stop is called or it finishes. If wrapping is set, loop over the main trajectory until stop is called. )
TRAJSTOP [none] Stop the trajectory and return to 0 pressure
TRAJPAUSE [none] Pause the trajectory and hold pressure
TRAJRESUME [none] Resume the trajectory

Others

Command Arguments Description
DEFLOAD [none] Load default settings profile from onboard storage
DEFSAVE [none] Overwrite default settings profile settings to onboard storage
LCDTIME #1 int Set the desired refresh time for the LCD screen if attached (in ms)